UNISIGN · REPORT-MATCHED PVC BANNER SELECTION

Flame-Retardant PVC Banner Material

Choose a flame-retardant PVC banner by the exact model and report, not by a general product-family claim. B1 and NFPA 701 are different test routes. The required standard, banner model, report scope and printed condition must match the project.

A public UNISIGN SGS scan shows PVC COATED FABRICS tested to DIN 4102-1 with a B1 result. The visible page does not name a model or state the printed condition. Ask us to match the current full report to your quotation before approval.

SGS test report scan for PVC coated fabrics tested to DIN 4102-1 with B1 result
Public report scan for PVC COATED FABRICS. Use the complete current report and exact SKU match for project approval.
2 test routesB1 and NFPA 701 must be checked separately
1 public B1 scanSGS scan for PVC COATED FABRICS
4 banner familiesFrontlit, backlit, blockout and mesh
1 approval ruleExact SKU + exact report + exact use

Which PVC Banner Is Flame Retardant?

The correct answer is the exact model covered by an acceptable, current test report. A category name, model suffix, old scan or supplier statement is not enough. First ask the venue, buyer or authority which standard it accepts. Then match that requirement to the model code on the sample, quote and roll label.

For a B1 request, check the DIN 4102-1 report scope. For an NFPA 701 request, ask for the NFPA 701 report for the exact model. These two results should not be treated as equal or interchangeable.

What Public Evidence Is Available Now?

The public certificate area includes an SGS report scan. The visible page supports the facts below. It does not support a claim that every PVC banner or every current model has the same result.

Evidence fieldWhat the public scan showsWhat still needs confirmation
Testing organizationSGSAsk for the complete current report and all pages.
Sample descriptionPVC COATED FABRICSMatch this description to the exact ordered SKU and construction.
StandardDIN 4102-1 (May 1998)Confirm the buyer accepts this standard and edition.
Result shownMeets class B1Confirm the result is within the full report scope and remains current for the order.
Report year2018 public scanRequest the latest available document.
Exact model on visible pageNot shownRequire a written report-to-SKU match.
Printed or unprinted conditionNot stated on the visible pageCheck ink, print coverage, finishing and sample condition.
Important: the B1 public scan is useful evidence, but it is not a blanket certificate for the full PVC banner range. A model name that contains “B1” is also not proof by itself.

B1 vs NFPA 701: Do Not Treat Them as the Same

Buying pointB1 / DIN 4102-1NFPA 701What to ask
Test routeClassification under DIN 4102-1 for building materials.Fire-test methods for flame propagation of textiles and films.Which named standard and edition does the project require?
Common requestOften requested in Germany and some European projects.Often requested for fabrics, films and hanging decorative materials in the United States.Which local authority or venue reviews the document?
Can one replace the other?No automatic equivalence. Acceptance depends on the project and authority.Get written acceptance before production.
What the report must matchExact model, material build, test sample, report number, issuer, date and use condition.Ask for the full report, not only a logo or first page.
Printed conditionPrinting, ink load, coating, seaming, hemming or other finishing may affect acceptance.State whether the project needs printed-material evidence.

Primary definitions: DIN Media — DIN 4102-1 and NFPA — NFPA 701. The approving authority decides what is accepted for a project.

Exact Model and Report Matching Table

These are practical UNISIGN starting models for four banner uses. They are not listed here as certified models. The fire-report status must be checked for the exact model and order.

Starting modelBanner typeListed weightListed widthPrint routeFire-report status for this page
CFM11/510Coated frontlit, matte510 g/m²Up to 5 mSolvent, eco-solvent, UV, latexMatch required. Request the current report for this exact SKU.
LBG51/610Laminated backlit610 g/m²Up to 5 mSolvent, eco-solvent, UV, latexMatch required. Do not extend another model’s report to this SKU.
CDM2525/510Coated double-side blockout510 g/m²Up to 5 mSolvent, eco-solvent, UV, latexMatch required. Confirm both material build and printed condition.
M1212NPCoated mesh with liner360 g/m²Up to 5 mSolvent, eco-solvent, UV, latexMatch required. Confirm liner, mesh build and exact report scope.

4 PVC Banner Types to Start the Report Check

A product list with images helps a buyer identify the use, surface and model to sample. The image is a visual guide. The model code, current TDS, report, quotation and roll label control the order.

UNISIGN coated frontlit PVC banner material roll

FRONTLIT STARTING MODEL

CFM11/510

  • 510 g/m²
  • Matte frontlit surface
  • Up to 5 m listed
  • Current fire report must match

Check CFM11/510 Report

UNISIGN LBG51 610 laminated backlit PVC banner roll

BACKLIT STARTING MODEL

LBG51/610

  • 610 g/m²
  • For illuminated display tests
  • Up to 5 m listed
  • Current fire report must match

Check LBG51/610 Report

UNISIGN CDM2525 coated blockout PVC banner material roll

BLOCKOUT STARTING MODEL

CDM2525/510

  • 510 g/m²
  • Double-side blockout build
  • Up to 5 m listed
  • Current fire report must match

Check CDM2525/510 Report

UNISIGN M1212NP coated PVC mesh banner material with liner

MESH STARTING MODEL

M1212NP

  • 360 g/m²
  • Coated mesh with liner
  • Up to 5 m listed
  • Current fire report must match

Check M1212NP Report

7 Steps Before You Approve a Flame-Retardant Banner

  1. Name the standardWrite B1 / DIN 4102-1, NFPA 701 or the exact local requirement.
  2. Name the authorityRecord the venue, buyer, inspector or authority that accepts the document.
  3. Lock the SKUUse the same model code on the sample, quote, report match and roll label.
  4. Read the full reportCheck issuer, number, date, method, sample description, result and limitations.
  5. Match the buildCheck weight, coating, liner, face, width and any other construction detail.
  6. State print statusSay whether the report must cover printed, unprinted or finished material.
  7. Get acceptanceSend the document pack to the approving party before bulk production.

What to Put in the RFQ

01 · DOCUMENT

Required fire standard

State B1 / DIN 4102-1, NFPA 701 or another named standard. Add the required edition if known.

02 · PRODUCT

Banner type and build

List frontlit, backlit, blockout or mesh, plus target weight, width, roll length and model.

03 · PRINT

Printer and ink

Provide printer, ink family, print coverage and whether evidence is needed after printing.

04 · FINISHING

Final construction

List welding, hems, eyelets, pole pockets, seams, liner removal and other finishing.

05 · USE

Venue and installation

State indoor or outdoor use, hanging method, display size, destination and approving party.

06 · ORDER

Quantity and deadline

Add sample quantity, production volume, delivery country and approval deadline.

Fastest document check: send the required standard, intended model, printed/unprinted requirement, destination, venue and deadline in one message. We can then identify which report questions must be resolved before sampling.

Related PVC Banner Selection Tools

Flame-Retardant PVC Banner FAQ

Is all PVC banner material flame retardant?

No. Do not apply one report or a general family statement to every model. Confirm the exact SKU, material build and report scope.

What is a B1 banner?

In this buying context, it means a banner model supported by an acceptable DIN 4102-1 result showing class B1. The report must match the ordered material.

Is B1 the same as NFPA 701?

No. They are different standards and test routes. A B1 report does not automatically prove NFPA 701 acceptance, and the reverse is also true.

Does UNISIGN have public B1 evidence for PVC banner?

Yes. A public SGS scan shows PVC COATED FABRICS tested to DIN 4102-1 with a B1 result. The visible page does not identify an exact SKU, so a current full report and written model match are still required.

Does this page prove that CFM11/510, LBG51/610, CDM2525/510 or M1212NP is certified?

No. They are starting models for a report check. Ask for the current report that covers the exact model before making a compliance claim.

Can a model name that contains “B1” be used as proof?

No. A model name is not a test report. Use the report number, issuer, date, sample description, method, result and written SKU match.

Does a report for unprinted banner also cover printed banner?

Do not assume this. Ask whether ink, print coverage and finishing are inside the report scope or accepted by the project authority.

What should I send for a report-matching request?

Send the required standard, authority or venue, exact model or banner type, weight, width, printer and ink, printed condition, finishing, quantity, destination and deadline.

Can UNISIGN guarantee approval by every venue?

No supplier can replace the final decision of the authority or venue. UNISIGN can provide the available document pack and product details for review.

Request a Model, Sample and Report Match

Tell us the standard, venue, banner type, print condition, width, ink, quantity and deadline. We will use those details to check the exact model and available documents.

Start the Document Check

Product information: UNISIGN · Reviewed September 16, 2026. Fire-test acceptance depends on the exact model, report scope, printed condition and approving authority. Request the current TDS and full report before ordering. About UNISIGN · Contact the PVC banner team.

Request a Flame-Retardant PVC Banner Match

Get Factory Price And Free Samples Right Now!

Just provide a few details and we will help you get quick quotes!